Product - Nova Instruments Pvt. Ltd. |
|
|
|
|
|
SEED GRAMINATOR |
|
|
|
(SINGLE CHAMBER WITH REFRIGERATION SYSTEM) [DIGITAL MICRO CONTROL/MICROPROCESSOR BASED MODEL] |
|
INTRODUCTION For Seed Testing Instruments And Germinator in Ahmedabad, Baroda, Surat |
“NOVA” Seed Germinator can generate and maintain above amb. temp, below ambient temp. & humidity. It is specifically designed for application of various testing under low temp.and with control humidity especially for Seed Germination. |
|
SALIENT FEATURES : |
- Fully automatic, temp. control-Micro control Based/PID
- Obstruction free working space.
- Easy to operate.
- Top Control Penal.
- Castor wheel for easy move ability.
- Dig. Temp. Indicator & Control (Micro Control/PID Based
- Floor model.
- Sensitive Temperature sensor Pt-100 type
- Forced air circulation.
- Elegant outlook powder coated.
- Digital display for dry & wet.
- Glass door to see through.
- Stainless Steel steam boiler.
- Humidity Control by dry & wet principal for Micro-Control Direct % RH in PID Contro
- Solid State electronic circuit.
- Seed Germinator can also be supplied without cooling system.
- Uniform temperature.
- Panel Meters – Volt & Ampere.
- Solid State electronic circuit.
- Auto Water Level Control.
- Seed Germinator can also be supplied without cooling system.
|
|
|
|
|
APPLICATION : |
These Seed Germinator are used for Seed Testing Lab., Seed Certification Agencies, Agricultural Research Institutes, etc.. |
|
CONSTRUCTION: |
The unit is of double walled construction. The exterior chamber is made of mild steel & finished in non corrosive paint or powder coated and interior chamber is made of heavy gauge polished stainless steel. Between two chamber glass-wool insulation is provided. Glass window/Door is provided to see the operation without disturbing the control condition inside the chamber. An outside metal door with lock is provided. The unit rest on castor wheel. 5/6 removable tray at fix distance are provided. Forced air circulation for uniform temperature. 2 Nos. Digital Display indicating Dry & Wet temp. Humidity by steam injection control by dry & wet bulb principal and set by chart provided.Nova Instruments For Seed Testing Instruments in Ahmedabad, Seed Testing Instruments in Baroda, Seed Testing Instruments in Surat, Seed Testing Instruments in Rajkot, Seed Germinator in Ahmedabad, Seed Germinator in Baroda, Seed Germinator in Surat. |
|
HEATING: |
[A] Chamber is heated by long lasting air heater. [B] Boiler heater is of immersion type. |
|
COOLING: |
Using hermetically sealed compressor coupled with evaporation coil & fan cool Condenser. |
|
HUMIDITY: |
Humidity generated by steam injection near the duck from a boiler connected to water tank fitted with water level controller. Humidity set & derived by dry & wet bulb principles by the provided depression chart OR by solid state Electronic sensor in PID Control for Direct % RH Indicator and Controller. |
|
INDICATION & CONTROL: |
Digital display indication for temperature Dry & Wet, Fully automatic solid state electronic controllers with Pt-100 sensors for both dry & wet bulb controllers are panel type easy for maintenance & service OR by solid state Electronic sensor in PID Control for Direct % RH Indicator and Controller. |
|
CONTROL PANEL: |
Control panel is provided on the top of the unit consisting of Mains switch,Mains indicator,Amp. meter, Voltmeter, Wet bulb Digital Indicator cum Controller, Wet bulb Indication pilot lamp, Dry bulb Digital Indicator cum Controller, Dry bulb indication pilot lamp (For cooling cycle-heating cycles), Low water level controller fitted & connected through circuit to boiler heater low level pilot lamp (will not glow if water level is below requirements) OR PID Controller in place of Dry & Wet Bulb Digital Controller. |
|
TECHNICAL SPECIFICATION: |
Temperature Range |
10 Deg. C to 60 Deg. C. |
Accuracy |
+/- 1 Deg. C. |
Humidity Range |
40 to 95% RH |
Humidity Accuracy |
+/- 3% RH |
Control |
Fully Automatic Digital |
Sensor |
Pt-100 type. |
Ammeter & Voltmeter for electrical parameter. |
Operating Voltage |
230 V Single phase 50Hz AC Supply.
|
|
|
CAPACITY (Cuft) |
INNER DIMN. IN CMS (H x W x D) |
TEMP. RANGE
ACCU.+/-1 DEG.C |
HUMIDITY RANGE ACCU.+/-3% RH |
CHAMBER |
6 Cuft |
70 x 50 x 50 |
10 to 60 Deg. C. |
90
to
95%
RH |
Single |
8 Cuft |
80 x 55 x 50 |
10 to 60 Deg. C. |
Single |
10 Cuft |
90 x 55 x 55 |
10 to 60 Deg. C. |
Single |
12 Cuft |
90 x 65 x 58 |
10 to 60 Deg. C. |
Single |
16 Cuft |
90 x 70 x 70 |
10 to 60 Deg. C. |
Single |
|
|
|
|
OPTIONAL ACCESSORIES: |
* Suitable Voltage Stabilizer
* Chamber illum. with Prog. Timer. |
|
NOTE: |
ALL THE CONTROLLERS & SENSORS ARE PROVIDED WITH TEST & CALIBRATION sREPORTS FROM OUR ASSOCIATE M/S. NOVA CALIBRATION CENTRE HAVING |